Control solar panel simulator Nets through the Lager CLI. Solar simulation enables testing of solar-powered devices by simulating various irradiance conditions, temperatures, and panel characteristics.

Syntax

lager solar [OPTIONS] NET_NAME COMMAND [ARGS]...

Global Options

OptionDescription
--box BOXLagerbox name or IP address
--helpShow help message and exit

Commands

CommandDescription
setInitialize and start solar simulation mode
stopStop solar simulation mode
irradianceSet or read irradiance (W/m²)
mpp-currentRead maximum power point current (A)
mpp-voltageRead maximum power point voltage (V)
resistanceSet or read dynamic panel resistance (Ω)
temperatureRead cell temperature (°C)
vocRead open-circuit voltage (V)

Command Reference

set

Initialize and start the solar simulation mode.
lager solar NET_NAME set [--box BOX]
This command configures the power supply to operate in solar panel simulation mode, enabling I-V curve emulation.

stop

Stop the solar simulation mode and return to normal operation.
lager solar NET_NAME stop [--box BOX]

irradiance

Set or read the irradiance level in watts per square meter (W/m²).
lager solar NET_NAME irradiance [VALUE] [--box BOX]
Arguments:
  • VALUE - Irradiance value in W/m² (0.0 - 1500.0). If omitted, reads current value.
Examples:
# Set irradiance to 1000 W/m² (standard test condition)
lager solar SOLAR1 irradiance 1000

# Read current irradiance
lager solar SOLAR1 irradiance

mpp-current

Read the maximum power point (MPP) current in amps.
lager solar NET_NAME mpp-current [--box BOX]
Returns the current at which the simulated solar panel produces maximum power.

mpp-voltage

Read the maximum power point (MPP) voltage in volts.
lager solar NET_NAME mpp-voltage [--box BOX]
Returns the voltage at which the simulated solar panel produces maximum power.

resistance

Set or read the dynamic panel resistance in ohms.
lager solar NET_NAME resistance [VALUE] [--box BOX]
Arguments:
  • VALUE - Resistance value in Ω (0.1 - 100.0). If omitted, reads current value.

temperature

Read the simulated cell temperature in degrees Celsius.
lager solar NET_NAME temperature [--box BOX]

voc

Read the open-circuit voltage (Voc) in volts.
lager solar NET_NAME voc [--box BOX]
Returns the voltage when no load is connected to the simulated solar panel.

Examples

# Start solar simulation mode
lager solar SOLAR_PANEL set --box my-lager-box

# Set irradiance to standard test condition (1000 W/m²)
lager solar SOLAR_PANEL irradiance 1000

# Read MPP voltage and current
lager solar SOLAR_PANEL mpp-voltage
lager solar SOLAR_PANEL mpp-current

# Read open-circuit voltage
lager solar SOLAR_PANEL voc

# Set panel resistance
lager solar SOLAR_PANEL resistance 5.0

# Stop solar simulation
lager solar SOLAR_PANEL stop

Supported Hardware

ManufacturerModel SeriesFeatures
EAPSI/EL seriesTwo-quadrant operation, I-V curve simulation
EAPSB 10060-60Bidirectional power supply
EAPSB 10080-60Bidirectional power supply

Solar Panel Simulation Concepts

I-V Curve

Solar panel simulators create an I-V (current-voltage) characteristic curve that mimics real solar panel behavior:
  • Short-circuit current (Isc): Maximum current when terminals are shorted
  • Open-circuit voltage (Voc): Voltage with no load
  • Maximum Power Point (MPP): Optimal operating point for maximum power

Standard Test Conditions (STC)

Industry standard for solar panel testing:
  • Irradiance: 1000 W/m²
  • Cell temperature: 25°C
  • Air mass: AM1.5

Notes

  • Solar simulation requires compatible bidirectional power supplies
  • The EA PSI/EL series supports two-quadrant operation for realistic simulation
  • Use lager nets to see available solar nets on your gateway
  • Irradiance values above 1500 W/m² are outside the valid range