Upgrade Notes
- Update your boxes. All of this release’s fixes run on the box, except the gateway retry
hint. Run
lager update --box <box-name>after you upgrade the CLI. - FTDI GPIO channels behave differently. These changes affect every FTDI GPIO user:
- A GPIO channel is never reset now, so a level stays set after the process that set it exits.
- The serial tty of an FTDI channel used for GPIO disappears on first use and stays gone until the part is re-plugged. The ttys of other channels are not touched.
- The output cache moved from
/tmp/ft232h_gpio_cache.jsonto/etc/lager/ftdi_gpio_cache.json. The box moves the old file once. - After a power-up (a box reboot or a re-plug) the pins sit at the chip’s idle level, all HIGH, until something opens the channel. The saved levels come back on first use, not at boot.
Bug Fixes
- A gateway’s “lager does not answer” now says to retry first. When a gateway answers
502withX-Gateway-Error: upstream_unavailable, the CLI now says the box service may be restarting and suggests retrying in a few seconds. It suggestslager updateorlager installonly if the failure persists. A box service restarts itself in about 4 s to recover a USB device. - A
/usb/commandthat restarts the service keeps the reason why. When a hub that would not open triggers the self-restart, the503 restartinganswer now carries the samereason_codeandreason_detailas the404answer. - FTDI GPIO outputs hold their level after the process that set them exits. A level set
from a
lager pythonscript, or bylager gpobefore the next script started, used to fall back to HIGH on every pin of the channel, because each open and close reset the channel.- The driver no longer resets a GPIO channel.
lager gpi,lager nets stateandNet.input()read output pins from the pin register, not a cached value.- Two nets on one channel no longer change each other’s direction.
- Levels survive a box restart and a box reboot.
- FTDI GPIO, I2C and SPI nets work again after the part is re-plugged. After an FTDI part
re-enumerated (a
lager usb <net> cycle, a power cut, a cable pull),lager gpo,lager gpi,lager i2c,lager spiandlager nets statefailed with[Errno 19] No such deviceorNo USB device with S/N ...untillager box-config restart. When an open fails because the box service’s USB device list is out of date, the drivers now refresh the list and open once more.