Upgrade Notes
-
A LabJack T7 opens over USB only. Before, a T7 opened with
ANY, so an unplugged T7 searched the network and held the device lock for minutes. Now a T7 that is not on USB fails in seconds with “not found on USB”. A Lager Box whose T7 is on Ethernet must runlager box-config env set LAGER_LABJACK_CONNECTION=ANY, thenlager box-config apply. -
lager i2caddresses andlager spi --fillread a bare number as decimal. Hex needs a0xprefix. Before,--address 72reached 0x72 and--fill 10sent 0x10. A script that passes--address 48for 0x48 must pass--address 0x48. The rule applies to--address,scan --start/--endand--fill, and bare hex digits such as1aare refused. -
User scripts no longer get
PIGPIO_ADDR. The Lager Box no longer looks for a pigpio container. A script that needs the variable must pass it with--env. -
lager installwith no target installs on this machine. On Linux it connects to 127.0.0.1 over SSH. Before, it stopped with “Either —box or —ip is required”.lager uninstallwith no target still stops with that error except on a Mac. To uninstall this machine, pass--ip 127.0.0.1.
Features
-
A Lager Box can run on an Apple silicon Mac.
lager installwith no target installs a Lager Box on the Mac that runs it.lager install --ip <mac>installs one on another Mac. A host agent owns the USB instruments, and the Box container asks the agent for each one. See Setting Up a Lager Box on a Mac. -
The Mac installer sets up the vendor libraries. It installs LabJack LJM,
libusb, SEGGER J-Link, PicoScope 7 and the ARM GDB, and reports each piece
that it cannot set up.
--skip-jlinkand--skip-picoscopeleave pieces out, andlager updateleaves out the same pieces. -
LabJack gpio nets can declare the level that they power up at. A LabJack
powers up with every pin as a pulled-up input, so a load on a gpio net saw
HIGH after a power cycle.
lager nets set-power-up NET... low|high|nonerecords a level on T7 and U3 nets.lager nets apply-power-upwrites each LabJack’s boot configuration, and--checkfails in CI when a level drifts. -
lager defaults add --energy-net,--i2c-netand--spi-net.lager energy,lager i2candlager spialready used a default net, and now an option can set one. Each option has a matchinglager defaults deletesubcommand.
Bug Fixes
-
lager debugmemory reads of 16 KiB and more fail. J-Link Commander reads counts as hex, and lager sent them in decimal. Lager now sends hex and splits a read at 0x4000 items. -
New firmware does not run after
lager debug <net> flashon a non-DA1469x J-Link target. The core stayed halted until a reset. Now the firmware runs, and--haltkeeps the core halted. -
Script calls to supply, battery, electronic load, EA and solar nets fail or
return nothing. Several
Net.getmethods called driver methods that do not exist, or returnedNone. They now return their readings, and a channel-less protection call acts on the net’s own output. (#843, #845, #846) -
Per-call I2C and SPI
overridesstay on the net after the call. The driver now returns to its configured settings after the call. An I2Cpull_ups-only override no longer resets the bus to 100 kHz. -
BLE
Central.connect()andCentral.pair()drop the client. They now return theClient.Client.start_notify(max_messages=N)returns when the Nth notification arrives. -
Olimex JTAG probes do not appear in
lager nets add. The Lager Box now lists and opens the four Olimex models, each with its own OpenOCD interface config. Devices whose target config OpenOCD 0.12 lacks now stop with a clear message before OpenOCD starts. (#850) -
lager nets statereports “no value from instrument” for an unreadable LabJack net. It now names the driver’s error, for example “not found on USB”. -
lager uninstallexits 0 after a step fails. It now exits 1 and keeps the saved box, so the uninstall can run again by name. -
lager box-config apply,restartandrepairrun an old copy ofstart_box.sh. They now run the deployed script withbash. They also reuse a currentlagerimage instead of rebuilding it, which saves about a minute. -
Default nets do not apply.
lager wattnow reads the default watt meter net.lager dac 3.3andlager gpo highread a lone value as the value. -
Smaller fixes.
lager battery <net> ocpaccepts 6.1 A on a Keithley 2281S.lager webcam stopsignals only its own stream.lager boxes add-allasks before it changes a saved box.lager logs clean --older-than Ncounts hours, not whole days. Install and update no longer warn about thelsusbanddfu-utilmounts.
Improvements
lager spi writeandlager spi transfer --datasplit a run of hex by the net’s word size.lager wattprints readings with SI prefixes, likelager energy.lager install --ipchecks for a terminal before it deploys to a Lager Box that needs a sudo password.lager battery disableasks with a default of no.lager i2candlager spi transferrefuse inline data together with--data-file.- No-op options are hidden from
--help.
Known Limitations
- On a Mac Lager Box, the first T7 ADC read after a DAC change can show the old value after the T7 is plugged in again. Restart the host agent to clear it.
- A Lager Box on another Mac is open to that Mac’s network, with no firewall. Install one only on a network that you trust.
- The Mac Lager Box does not support OpenOCD probes, Rigol oscilloscopes, serial-port supplies, webcams or BLE yet. See the Mac setup page for the full list.